  inductive and lvdt sensors for displacement, distance and position inductive displacement sensors, lvdt gaging sensors, displacement transducers, displacement sensors, distance, transducers, automation, automobile, automotive, loading sensor, non-contact, pressure resistant, pressure-resistant, immersion depth, spring travel, filling level, stroke, hydraulics, inductive sensors and gaging sensors, automotive engineering, pistons, clutch, measurement of lengths, linear sensor, lvdt, measurement devices, oem sensors, oil resistant, pneumatics, position sensor, position measurement, sensor, series sensors, unbalance sensor, valve, wear-free, displacement sensor, displacement measurement, also customer-specific oem sensors, automotive engineering test and test-rigs, automotive sensors for large-scale production linear sensors and gaging sensors for industrial and oem applications for integration in machines and systems. accurate displacement and position sensors to favourable conditions
lvdt series: gauging sensor with external electronics + signal measurement ranges 1 ? 10 mm extremely accurate even under difficult ambient conditions long-term stability, because wear-free easy fitting/operation 26 gauging sensor with plunger guided in plain bearings and fitted with return spring. the measuring probe is mounted via a standard m2.5 thread and can be interchanged with commercially available measurement probes. measurement probes are primarily used for the measurement and inspection of work-piece geometry (length, width, diameter, thickness, depth, height, etc.). probe tips linearity 3 ( 0.3 %) 1.5 ( 0.15 %) connection (axial): ca integral cable (3 m) sa plug connection gauging sensor option: v pneumatic push principle: differential transformator (lvdt) measuring range mm excitation ac function: gauging sensor article ?10 2 5 m2.5 ?4.5 5 6 m2.5 5 10 ?4.5 m2.5 45 standard option: 11 type option: type13 dta- g- 5 3-ca v -
27 gauging sensor type - sa-v with pneumatic push dimensions apply for all models female connector dimensions apply for all models female connector 90 gauging sensor type - ca with integral cable gauging sensor type -sa with axial connection basic model connection ca sa opt. v ca sa opt. v ca sa opt. v ca sa opt. v length of housing l mm 67 67 69 89 89 92,1 108 108 120 135 135 145 length of clamping cylinder l 1 mm 21 21 19 26 26 25,1 30 30 38 42 42 46 length of plunger l * mm 9.5 9.5 10 12.5 12.5 12.7 14 14 17.5 20 20 22.2 * plunger in zero position (10 % fso 1 mm) dta-1g- dta-3g- dta-5g- dta-10g- 26.5 30 20.5 11.4 ?14 ~36 ~40 ~63 ?14 13 l ?8h6 ?10 l l1 inside diameter hose ?2 9 8 3.5 il ?8h6 ?10 l1 9 il ?8h6 ?10 l1 model connection ca sa ca sa ca sa ca sa measuring range standard 0.3 % fso optional 0.15 % fso repeatability <0.0075 % excitation frequency excitation amplitude sensitivity spring force temperature range options operating temperature storage temperature zero sensitivity housing protection class minimum cable bending radius outerdiametercable iec 68-2-29 iec 68-2-27 vibration iec 68-2-6 fso = full scale output *) depends on connector temperature stability sa: ip 40 / ip 54 * ca: ip 54 50 ppm / c 10 hz ... 58 hz 1.5 mm / 58 hz ... 500 hz 20 g 40 g, 1000 shocks / axis 100 g, 3 shocks / axis shock stainless steel incl. magnetic shielding ~4,6 mm 20 mm 0.22 n/mm 0.14 n/mm 0.12 n/mm 0.08 n/mm dta-1g- dta-3g- dta-5g- dta-10g- 1.00 n <0.15 m <0.45 m force in midrange (typical) 5khz 0.95 n 85 mv/vmm 53 mv/vmm 133 mv/vmm linearity 1 mm 3 mm 3m 9m 18 m 6m 30m 60m 5 mm 10 mm 100 ppm / c 44 mv/vmm 15 m 30 m 1.18 n 1.23 n <1.5 m <0.75 m 2khz 5v eff -20 c ... 80 c -40c...+80c -20c...+80c option v with pneumatic push
the msc710 is a single-channel miniature sensor controller for the operation of inductive displacement sensors based on the lvdt principle (linear variable differential transformer). its compact, but rugged design, makes it suitable for both industrial and laboratory applications. easily accessible and simple to operate, by using dip-switches. the electronic unit can be matched to a wide range of sensors. msc710 sensor controller for lvdt series excellent linearity and resolution zero and gain adjustable coarse/fine excitation frequency 1 ... 10 khz (selectable) compact and robust emi-proofed housing 42 plunger magnetic core primary coil secondary coil lvdt-sensor supply signal potentiometer: zero gain offset dip-switches: frequency phase sensor voltage test 40 38 mounting hole ? 4.2 terminal block cable sleeve housing dimensions 52 x 50 x 35 mm u u i sec- sec+ prim- prim+ mid1 mid2 output power pgnd ognd 11 j3 limit j5 j6 j7 x1 x3 x4 x5 gain test frequ. shield shield r3 r2 r1 1 2 3 4 j2 on 1 2 3 4 j1 on j4 1 2 on 1 2 on
43 msc710-u msc710-i sensor gain zero 2 ... 10 vdc (r a >1 kohm) 4 ... 20 ma (load <500 ohm) <1.5mv eff *<3a eff * <15mv ss <30a ss storage operating 0c...+70c temperature range fso = full scale output * rms ac-measuring, frequency 3 hz ... 300 hz en 50081-2 (spurious emission) vibration shock en 60068-2-64 (noise) en 60068-2-29 (continous shock) electromagnetic compatibility (emc) en 50082-2 (immunity to interference) housing material weight protection class abs-plastic ip 65 -40c...+85c 80 g -20 ...+350 % (trimpot) output signal temperature stability 100 pmm / c 50 % (trimpot) range frequency response linearity 300 hz (-3db) 150 ... 400 mv 1/2/5 khz (selectable by dip-switches) <0.02 % fso 10 kohm noise model 18 ... 30 vdc (18 ... 45 ma) reverse plarity protection, overvoltage protection input impedance sensor principle sensor excitation for lvdt sensors power supply protection
modifications reserved / y9761177-a020076jkr more precision. sensors and systems sensors and measurement devices measurement systems for displacement, position and dimension for non-contact temperature measurement for online/offline quality control www.micro-epsilon.com 8120 micro-epsilon usa brownleigh dr. raleigh, nc 27617 / usa phone +1/919/787-9707 fax +1/919/787-9706 info@micro-epsilon.us micro-epsilon headquarters koenigbacher str. 15 94496 ortenburg / germany tel. +49 (0) 8542 / 168-0 fax +49 (0) 8542 / 168-90 info@micro-epsilon.com micro-epsilon uk ltd. dorset house, west derby road liverpool, l6 4br info@micro-epsilon.co.uk phone +44 (0) 151 260 9800 fax +44 (0) 151 261 2480


▲Up To Search▲   

 
Price & Availability of DTA-3G-15-SAV

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X